SENSOR CROSS SENSITIVITY CHART

SENSIT GOLD G2, GOLD, GOLD CGI, HXG-2D, HXG-3

NOTE: READINGS RELATIVE TO METHANE CALIBRATION. READINGS MAY VARY BASED ON SENSOR AGE AND CONDITION.

GAS OR VAPOURFORMULASENSITIVITY (PPM)100 LEL %READING @ 10% LEL
Butane(CH3) 3CH2523%
HydrogenH25048%
MEKCH3COCH2CH21001.80.6%
MethaneCH410510%
MethanolCH3OH5062.5%
N-HexaneCH3(CH2)4CH34001.20.2%
PentaneC5H12251.55%
PropaneC3H8102.26%
R-22CHCLF250N/AN/A
R-507R125 + R143A100N/AN/A
R-410AR32 + R125100N/AN/A